From df3af70b33eb6372b56075bc9e45c23ccf3f82c6 Mon Sep 17 00:00:00 2001
From: riku <risaku@163.com>
Date: 星期二, 28 十月 2025 17:40:38 +0800
Subject: [PATCH] 2025.10.28 1. 新增巡查场景历史详情界面出版(完成); 2. 巡查任务日历界面,任务条目中新增风险提示、巡查要点、应急巡查3种提示信息的提示图标逻辑(待完成);

---
 app/src/main/java/cn/flightfeather/thirdappmodule/module/inspection/InspectionDetailActivity.kt |  232 +++++++++++++++++++++++++++++++++++++++++++++++----------
 1 files changed, 189 insertions(+), 43 deletions(-)

diff --git a/app/src/main/java/cn/flightfeather/thirdappmodule/module/inspection/InspectionDetailActivity.kt b/app/src/main/java/cn/flightfeather/thirdappmodule/module/inspection/InspectionDetailActivity.kt
index 0323bba..5522c5d 100644
--- a/app/src/main/java/cn/flightfeather/thirdappmodule/module/inspection/InspectionDetailActivity.kt
+++ b/app/src/main/java/cn/flightfeather/thirdappmodule/module/inspection/InspectionDetailActivity.kt
@@ -75,6 +75,22 @@
     //鑿滃崟鎸夐挳鍒楄〃
     protected val menuList = ArrayList<LinearLayout>()
 
+    private lateinit var ln_patrol_problem_recheck :LinearLayout
+    private lateinit var ln_patrol_take_evidence :LinearLayout
+    private lateinit var ln_patrol_problem_list :LinearLayout
+    private lateinit var ln_patrol_change :LinearLayout
+    private lateinit var ln_patrol_camera :LinearLayout
+    private lateinit var ln_patrol_newgit :LinearLayout
+    private lateinit var ln_patrol_promiss :LinearLayout
+    private lateinit var ln_patrol_rate :LinearLayout
+    private lateinit var ln_patrol_navi :LinearLayout
+    private lateinit var ln_patrol_chose_latlng :LinearLayout
+    private lateinit var ln_patrol_edit :LinearLayout
+    private lateinit var ln_patrol_share :LinearLayout
+    private lateinit var ln_patrol_check :LinearLayout
+    private lateinit var ln_patrol_change_check :LinearLayout
+    private lateinit var ln_patrol_pic_evidence :LinearLayout
+
     private var problemEditable = false
 
     private var timer = Timer("track")
@@ -260,26 +276,43 @@
         val iconPage1 = View.inflate(this, R.layout.page_patrol_icons_first, null)
         val iconPage2 = View.inflate(this, R.layout.page_patrol_icons_second, null)
 
+        ln_patrol_problem_recheck = iconPage1.findViewById(R.id.ln_patrol_problem_recheck)
+        ln_patrol_take_evidence = iconPage1.findViewById(R.id.ln_patrol_take_evidence)
+        ln_patrol_problem_list = iconPage1.findViewById(R.id.ln_patrol_problem_list)
+        ln_patrol_change = iconPage1.findViewById(R.id.ln_patrol_change)
+        ln_patrol_camera = iconPage1.findViewById(R.id.ln_patrol_camera)
+        ln_patrol_newgit = iconPage1.findViewById(R.id.ln_patrol_newgit)
+        ln_patrol_promiss = iconPage1.findViewById(R.id.ln_patrol_promiss)
+        ln_patrol_rate = iconPage1.findViewById(R.id.ln_patrol_rate)
+        ln_patrol_navi = iconPage2.findViewById(R.id.ln_patrol_navi)
+        ln_patrol_chose_latlng = iconPage2.findViewById(R.id.ln_patrol_chose_latlng)
+        ln_patrol_edit = iconPage2.findViewById(R.id.ln_patrol_edit)
+        ln_patrol_share = iconPage2.findViewById(R.id.ln_patrol_share)
+        ln_patrol_check = iconPage2.findViewById(R.id.ln_patrol_check)
+        ln_patrol_change_check = iconPage2.findViewById(R.id.ln_patrol_change_check)
+        ln_patrol_pic_evidence = iconPage2.findViewById(R.id.ln_patrol_pic_evidence)
         menuList.apply{
-            add(iconPage1.findViewById(R.id.ln_patrol_problem_recheck))
-            add(iconPage1.findViewById(R.id.ln_patrol_take_evidence))
-            add(iconPage1.findViewById(R.id.ln_patrol_problem_list))
-            add(iconPage1.findViewById(R.id.ln_patrol_change))
-            add(iconPage1.findViewById(R.id.ln_patrol_camera))
-            add(iconPage1.findViewById(R.id.ln_patrol_newgit))
-            add(iconPage1.findViewById(R.id.ln_patrol_promiss))
-            add(iconPage1.findViewById(R.id.ln_patrol_rate))
-            add(iconPage2.findViewById(R.id.ln_patrol_navi))
-            add(iconPage2.findViewById(R.id.ln_patrol_chose_latlng))
-            add(iconPage2.findViewById(R.id.ln_patrol_edit))
-            add(iconPage2.findViewById(R.id.ln_patrol_share))
-            add(iconPage2.findViewById(R.id.ln_patrol_check))
-            add(iconPage2.findViewById(R.id.ln_patrol_change_check))
-            //鍒ゆ柇鐢ㄦ埛鏉冮檺锛屽彧鏈夌鐞嗗憳鍙闂瀹℃牳鍥炬爣
-            if (viewModel.userTypeId != Domain.USER_ADMIN.toByte()) {
-                menuList[menuList.lastIndex - 1].visibility = View.INVISIBLE
-                menuList.last().visibility = View.INVISIBLE
-            }
+            add(ln_patrol_problem_recheck)
+            add(ln_patrol_take_evidence)
+            add(ln_patrol_problem_list)
+            add(ln_patrol_change)
+            add(ln_patrol_camera)
+            add(ln_patrol_newgit)
+            add(ln_patrol_promiss)
+            add(ln_patrol_rate)
+            add(ln_patrol_navi)
+            add(ln_patrol_chose_latlng)
+            add(ln_patrol_edit)
+            add(ln_patrol_share)
+            add(ln_patrol_check)
+            add(ln_patrol_change_check)
+            add(ln_patrol_pic_evidence)
+        }
+
+        //鍒ゆ柇鐢ㄦ埛鏉冮檺锛屽彧鏈夌鐞嗗憳鍙闂瀹℃牳鍥炬爣
+        if (viewModel.userTypeId != Domain.USER_ADMIN.toByte()) {
+            ln_patrol_check.visibility = View.INVISIBLE
+            ln_patrol_change_check.visibility = View.INVISIBLE
         }
 
         vp_patrol_icons.adapter = IconsPageAdapter(ArrayList<View>().apply {
@@ -428,6 +461,14 @@
                         CameraPosition(LatLng(s.latitude, s.longitude), zoomLevel, 0F, 0F)
                 )
         )
+
+        // 2025.10.22 褰撳満鏅槸宸ュ湴绫诲瀷鏃讹紝鏄剧ず淇敼鏂藉伐闃舵鎸夐挳
+        if (s.typeid.toString() == Constant.SCENE_TYPE_SITE) {
+            scene_status.visibility = View.VISIBLE
+        } else {
+            scene_status.visibility = View.GONE
+        }
+        scene_detail.setOnClickListener(this)
     }
 
     /**
@@ -453,15 +494,41 @@
         menuList.let {m ->
             when (status) {
                 Domain.TASK_STATUS_WAITING -> {
-                    for (i in m.indices) {
-                        if (i <= 7 || i == 12 || i == 13) {
-                            m[i].alpha = 0.2F
-                            m[i].setOnClickListener(showNeedStartTaskListener())
-                        } else {
-                            m[i].alpha = 1F
-                            m[i].setOnClickListener(this)
-                        }
+//                    for (i in m.indices) {
+//                        if (i <= 7 || i == 12 || i == 13) {
+//                            m[i].alpha = 0.2F
+//                            m[i].setOnClickListener(showNeedStartTaskListener())
+//                        } else {
+//                            m[i].alpha = 1F
+//                            m[i].setOnClickListener(this)
+//                        }
+//                    }
+                    listOf(
+                            ln_patrol_problem_recheck,
+                            ln_patrol_take_evidence,
+                            ln_patrol_problem_list,
+                            ln_patrol_change,
+                            ln_patrol_camera,
+                            ln_patrol_newgit,
+                            ln_patrol_promiss,
+                            ln_patrol_rate,
+                            ln_patrol_check,
+                            ln_patrol_change_check,
+                            ln_patrol_pic_evidence
+                    ).forEach {
+                        it.alpha = 0.2F
+                        it.setOnClickListener(showNeedStartTaskListener())
                     }
+                    listOf(
+                            ln_patrol_navi,
+                            ln_patrol_chose_latlng,
+                            ln_patrol_edit,
+                            ln_patrol_share
+                    ).forEach {
+                        it.alpha = 1F
+                        it.setOnClickListener(this)
+                    }
+
                 }
                 Domain.TASK_STATUS_RUNNING -> {
                     m.forEach {
@@ -470,25 +537,80 @@
                     }
                 }
                 Domain.TASK_STATUS_FINISHED -> {
-                    for (i in m.indices) {
-                        if (i == 1) {
-                            m[i].alpha = 0.2F
-                            m[i].isClickable = false
-                        } else {
-                            m[i].alpha = 1F
-                            m[i].setOnClickListener(this)
-                        }
+//                    for (i in m.indices) {
+//                        if (i == 1) {
+//                            m[i].alpha = 0.2F
+//                            m[i].isClickable = false
+//                        } else {
+//                            m[i].alpha = 1F
+//                            m[i].setOnClickListener(this)
+//                        }
+//                    }
+                    listOf(
+                            ln_patrol_take_evidence,
+                            ln_patrol_pic_evidence
+                    ).forEach {
+                        it.alpha = 0.2F
+                        it.isClickable = false
                     }
+                    listOf(
+                            ln_patrol_problem_recheck,
+                            ln_patrol_problem_list,
+                            ln_patrol_change,
+                            ln_patrol_camera,
+                            ln_patrol_newgit,
+                            ln_patrol_promiss,
+                            ln_patrol_rate,
+                            ln_patrol_navi,
+                            ln_patrol_chose_latlng,
+                            ln_patrol_edit,
+                            ln_patrol_share,
+                            ln_patrol_check,
+                            ln_patrol_change_check
+                    ).forEach {
+                        it.alpha = 1F
+                        it.setOnClickListener(this)
+                    }
+
                 }
             }
             if (viewModel.userTypeId == Domain.USER_COMPTENT.toByte()) {
-                for (i in m.indices) {
-                    when (i) {
-                        1, in 3..4, in 7..11 -> {
-                            m[i].alpha = 0.2F
-                            m[i].isClickable = false
-                        }
-                    }
+//                for (i in m.indices) {
+//                    when (i) {
+//                        1, in 3..4, in 7..11 -> {
+//                            m[i].alpha = 0.2F
+//                            m[i].isClickable = false
+//                        }
+//                    }
+//                }
+//                ln_patrol_problem_recheck
+//                ln_patrol_take_evidence
+//                ln_patrol_problem_list
+//                ln_patrol_change
+//                ln_patrol_camera
+//                ln_patrol_newgit
+//                ln_patrol_promiss
+//                ln_patrol_rate
+//                ln_patrol_navi
+//                ln_patrol_chose_latlng
+//                ln_patrol_edit
+//                ln_patrol_share
+//                ln_patrol_check
+//                ln_patrol_change_check
+//                ln_patrol_pic_evidence
+                listOf(
+                        ln_patrol_take_evidence,
+                        ln_patrol_change,
+                        ln_patrol_camera,
+                        ln_patrol_rate,
+                        ln_patrol_navi,
+                        ln_patrol_chose_latlng,
+                        ln_patrol_edit,
+                        ln_patrol_share,
+                        ln_patrol_pic_evidence
+                ).forEach {
+                    it.alpha = 0.2F
+                    it.isClickable = false
                 }
             }
         }
@@ -706,6 +828,19 @@
 
     override fun onClick(v: View?) {
         when (v?.id) {
+            R.id.scene_detail -> {
+                val intent = Intent(this, MenuSceneHistoryActivity::class.java).apply {
+                    putExtra("scene", viewModel.scene.value)
+                }
+                startActivity(intent)
+            }
+            // 淇敼宸ュ湴鏂藉伐闃舵
+            R.id.scene_status ->{
+                val intent = Intent(this, MenuSceneInfoActivity::class.java).apply {
+                    putExtra("scene", viewModel.scene.value)
+                }
+                startActivity(intent)
+            }
             // 鏌ョ湅鎴栬幏鍙栫敤鎴疯处鎴蜂俊鎭�
             R.id.user_account -> {
                 val intent = Intent(this, MenuSceneAccountActivity::class.java).apply {
@@ -834,7 +969,7 @@
                 // fixme: 2020/8/3 姝ゅ浠ュ緪姹囧尯浣滀负娴嬭瘯锛岄鍏堜娇鐢ㄦ柊鐨勮瘎鍒嗚鍒欙紝涔嬪悗閫愭鏇挎崲
                 val intentEvaluation = if (viewModel.scene.value?.districtcode == "310104") {
                     Intent(this, MenuGradeActivity::class.java)
-                }else {
+                } else {
                     Intent(this, GradeActivity::class.java)
                 }
                 intentEvaluation.putExtra("inspectionGuid", viewModel.inspection.value?.guid)
@@ -888,6 +1023,17 @@
                 }
                 startActivity(intent)
             }
+            // 鏍规嵁浠绘剰鍥剧墖鍜岄缇界幆澧冪郴缁熶腑鐨勫彴璐﹀浘鐗囧垱寤洪棶棰�
+            R.id.ln_patrol_pic_evidence -> {
+                val intent = Intent(this, PicEvidenceActivity::class.java).apply {
+                    putExtra("subTask", viewModel.subTask.value)
+                    putExtra("inspection", viewModel.inspection.value)
+                    putExtra("scene", viewModel.scene.value)
+                    putExtra("lat", latitudeCurrent)
+                    putExtra("lng", longitudeCurrent)
+                }
+                startActivity(intent)
+            }
         }
     }
 }
\ No newline at end of file

--
Gitblit v1.9.3