From 7be66bc9663c1106ebc78748dc22f394680ac86b Mon Sep 17 00:00:00 2001
From: riku <risaku@163.com>
Date: 星期二, 29 十二月 2020 09:57:09 +0800
Subject: [PATCH] 1. 修复场景地图界面选择场景点时可能由于列表下标越界导致崩溃问题; 2. 修复自定义PagerAdapter时,没有重写destroyItem可能会导致的崩溃问题; 3. 修改数据库实体类MediaTypeAlias的主键id类型从龙变更为Long,否则无法自增; 4. 新增部分列表相关的工具函数;
---
app/src/main/java/cn/flightfeather/thirdapp/module/inspection/InspectionDetailActivity.kt | 95 +++++++++++++++++++++++++++++------------------
1 files changed, 58 insertions(+), 37 deletions(-)
diff --git a/app/src/main/java/cn/flightfeather/thirdapp/module/inspection/InspectionDetailActivity.kt b/app/src/main/java/cn/flightfeather/thirdapp/module/inspection/InspectionDetailActivity.kt
index a089439..32ca2de 100644
--- a/app/src/main/java/cn/flightfeather/thirdapp/module/inspection/InspectionDetailActivity.kt
+++ b/app/src/main/java/cn/flightfeather/thirdapp/module/inspection/InspectionDetailActivity.kt
@@ -3,7 +3,6 @@
import android.app.Activity
import android.arch.lifecycle.Observer
import android.arch.lifecycle.ViewModelProviders
-import android.content.DialogInterface
import android.content.Intent
import android.net.Uri
import android.os.Bundle
@@ -13,15 +12,16 @@
import android.view.View
import android.view.animation.AnimationUtils
import android.widget.LinearLayout
+import cn.flightfeather.thirdapp.CommonApplication
import cn.flightfeather.thirdapp.R
import cn.flightfeather.thirdapp.activity.GradeActivity
import cn.flightfeather.thirdapp.activity.MapActivity
import cn.flightfeather.thirdapp.activity.ProblemDetailActivity
import cn.flightfeather.thirdapp.activity.PromiseActivity
import cn.flightfeather.thirdapp.adapter.IconsPageAdapter
-import cn.flightfeather.thirdapp.bean.Mediafile
-import cn.flightfeather.thirdapp.bean.Scense
-import cn.flightfeather.thirdapp.bean.Subtask
+import cn.flightfeather.thirdapp.bean.entity.Mediafile
+import cn.flightfeather.thirdapp.bean.entity.Scense
+import cn.flightfeather.thirdapp.bean.entity.Subtask
import cn.flightfeather.thirdapp.bean.vo.ProblemlistVo
import cn.flightfeather.thirdapp.model.event.InspectionEvent
import cn.flightfeather.thirdapp.model.event.ProblemEvent
@@ -129,7 +129,7 @@
super.onCreate(savedInstanceState)
- initIconViewPager()
+// initIconViewPager()
initLocation()
ll_show_hide_detail.setOnClickListener(this)
@@ -140,25 +140,6 @@
viewModel.inspection.observe(this, Observer {
it?.apply {
- if (extension1 != null) {
- val list = extension1.split(";").map{str ->
- str.split(",").map {str2 ->
- str2.toDoubleOrNull() ?: 0.0
- }.takeIf { l-> l.size == 2 }.let {latLng->
- LatLng(latLng?.get(1) ?: 0.0, latLng?.get(0) ?: 0.0)
- }
- }
- drawPolyline(list)
- list.firstOrNull()?.let {p->
- myLatLngList.add(
- MyLatLng(
- p,
- drawableId = R.drawable.icon_mark_start_blue,
- selected = true
- )
- )
- }
- }
onDataLoaded(0)
}
})
@@ -329,8 +310,37 @@
result = result.and(it)
}
if (result) {
+ initIconViewPager()
showMenu()
refreshMenuStatus(taskStatus)
+
+ viewModel.inspection.value?.extension1?.let{
+ val list = it.split(";").map{str ->
+ str.split(",").map {str2 ->
+ str2.toDoubleOrNull() ?: 0.0
+ }.takeIf { l-> l.size == 2 }.let {latLng->
+ LatLng(latLng?.get(1) ?: 0.0, latLng?.get(0) ?: 0.0)
+ }
+ }
+ //閬撹矾鐩戞祴鐐瑰拰閬撹矾绫诲瀷鐨勫満鏅紝鐩存帴灞曠ず杞ㄨ抗锛涘叾浣欏満鏅彧鏈夌鐞嗗憳鍜屾斂搴滈儴闂ㄥ彲浠ユ煡鐪�
+ if (
+ (viewModel.scene.value?.typeid?.toString() == Constant.SCENE_TYPE9 || viewModel.scene.value?.typeid?.toString() == Constant.SCENE_TYPE10)
+ || (CommonApplication.getInstance().currentUser.usertypeid == 0.toByte() || CommonApplication.getInstance().currentUser.usertypeid == 2.toByte())
+ ) {
+ drawPolyline(list)
+ }
+
+ list.firstOrNull()?.let {p->
+ myLatLngList.add(
+ MyLatLng(
+ p,
+ drawableId = R.drawable.icon_mark_start_blue,
+ selected = true
+ )
+ )
+ }
+ }
+
} else {
toast("璇风瓑寰呮暟鎹姞杞藉畬鎴�")
}
@@ -573,14 +583,12 @@
private fun startTracking() {
if (
-// viewModel.scene.value?.typeid?.toString() != Constant.SCENE_TYPE9 ||
+ viewModel.subTask.value == null ||
viewModel.subTask.value?.status != Domain.TASK_STATUS_RUNNING
) return
//褰撶户缁墽琛屾鍦ㄨ繘琛屼腑鐨勪换鍔℃椂锛屾牴鎹槸鍚︽湁鍘嗗彶杞ㄨ抗璁板綍鏉ュ垽鏂槸鍚﹀紑鍚�
- if (viewModel.inspection.value?.extension1 != null) {
- needTracking = true
- }
+ needTracking = true
if (!needTracking || timerTaskRunning) return
@@ -596,8 +604,8 @@
timerTaskRunning = true
}
- val lng = round(longitudeCurrent * 1000) / 1000
- val lat = round(latitudeCurrent * 1000) / 1000
+ val lng = round(longitudeCurrent * 1000000) / 1000000
+ val lat = round(latitudeCurrent * 1000000) / 1000000
viewModel.inspection.value?.apply {
if (extension1 == null) {
@@ -616,9 +624,15 @@
val l1 = LatLng(lat, lng)
val l2 = LatLng(last[1], last[0])
val distance = AMapUtils.calculateLineDistance(l1, l2)
- if (distance >= 5) {
+ if (distance >= 1 && distance < 1000 && lat != 0.0 && lng != 0.0) {
extension1 = "${extension1};${lng},${lat}"
- drawPolyline(LatLng(lat, lng))
+ //閬撹矾鐩戞祴鐐瑰拰閬撹矾绫诲瀷鐨勫満鏅紝鐩存帴灞曠ず杞ㄨ抗锛涘叾浣欏満鏅彧鏈夌鐞嗗憳鍜屾斂搴滈儴闂ㄥ彲浠ユ煡鐪�
+ if (
+ (viewModel.scene.value?.typeid?.toString() == Constant.SCENE_TYPE9 || viewModel.scene.value?.typeid?.toString() == Constant.SCENE_TYPE10)
+ || (CommonApplication.getInstance().currentUser.usertypeid == 0.toByte() || CommonApplication.getInstance().currentUser.usertypeid == 2.toByte())
+ ) {
+ drawPolyline(LatLng(lat, lng))
+ }
}
}
}
@@ -628,7 +642,7 @@
}
private fun trackingDone() {
- if (!needTracking || !timerTaskRunning) return
+ if (!timerTaskRunning) return
aMap.moveCamera(CameraUpdateFactory.zoomTo(zoomLevel))
@@ -653,6 +667,7 @@
} else {
it.problemcount + 1
}
+ // fixme: 2020/9/1 姝ゅ鍘熸湰鐨勯�昏緫鏄柊澧炰竴涓棶棰樺悗锛屽悓姝ユ洿鏂板贰鏌ヤ俊鎭腑鐨勯棶棰樻暟锛岄敊璇紝搴旇灏嗘鏇存柊鎿嶄綔鐩存帴鐢辨柊澧為棶棰樻帴鍙g粺涓�瀹屾垚
viewModel.updateInspection(it)
}
@@ -669,10 +684,16 @@
//寮�濮嬪鑸�
private fun startNavi() {
- val sourceLatLng = LatLng(viewModel.scene.value?.getLatitude()!!, viewModel.scene.value?.getLongitude()!!)
-
- val amapNavi = AmapNavi(this)
- amapNavi.startNavi(sourceLatLng.latitude, sourceLatLng.longitude)
+ if (viewModel.scene.value != null) {
+ val sourceLatLng = LatLng(
+ viewModel.scene.value!!.latitude,
+ viewModel.scene.value!!.longitude
+ )
+ val amapNavi = AmapNavi(this)
+ amapNavi.startNavi(sourceLatLng.latitude, sourceLatLng.longitude)
+ } else {
+ toast("瀵艰埅鐩墠涓嶅彲鐢紝璇风◢鍚庡啀璇�")
+ }
}
override fun onClick(v: View?) {
--
Gitblit v1.9.3