From 7be66bc9663c1106ebc78748dc22f394680ac86b Mon Sep 17 00:00:00 2001
From: riku <risaku@163.com>
Date: 星期二, 29 十二月 2020 09:57:09 +0800
Subject: [PATCH] 1. 修复场景地图界面选择场景点时可能由于列表下标越界导致崩溃问题; 2. 修复自定义PagerAdapter时,没有重写destroyItem可能会导致的崩溃问题; 3. 修改数据库实体类MediaTypeAlias的主键id类型从龙变更为Long,否则无法自增; 4. 新增部分列表相关的工具函数;

---
 app/src/main/java/cn/flightfeather/thirdapp/module/inspection/InspectionDetailActivity.kt |   94 ++++++++++++++++++++++++++++------------------
 1 files changed, 57 insertions(+), 37 deletions(-)

diff --git a/app/src/main/java/cn/flightfeather/thirdapp/module/inspection/InspectionDetailActivity.kt b/app/src/main/java/cn/flightfeather/thirdapp/module/inspection/InspectionDetailActivity.kt
index 8eeb114..32ca2de 100644
--- a/app/src/main/java/cn/flightfeather/thirdapp/module/inspection/InspectionDetailActivity.kt
+++ b/app/src/main/java/cn/flightfeather/thirdapp/module/inspection/InspectionDetailActivity.kt
@@ -3,7 +3,6 @@
 import android.app.Activity
 import android.arch.lifecycle.Observer
 import android.arch.lifecycle.ViewModelProviders
-import android.content.DialogInterface
 import android.content.Intent
 import android.net.Uri
 import android.os.Bundle
@@ -13,15 +12,16 @@
 import android.view.View
 import android.view.animation.AnimationUtils
 import android.widget.LinearLayout
+import cn.flightfeather.thirdapp.CommonApplication
 import cn.flightfeather.thirdapp.R
 import cn.flightfeather.thirdapp.activity.GradeActivity
 import cn.flightfeather.thirdapp.activity.MapActivity
 import cn.flightfeather.thirdapp.activity.ProblemDetailActivity
 import cn.flightfeather.thirdapp.activity.PromiseActivity
 import cn.flightfeather.thirdapp.adapter.IconsPageAdapter
-import cn.flightfeather.thirdapp.bean.Mediafile
-import cn.flightfeather.thirdapp.bean.Scense
-import cn.flightfeather.thirdapp.bean.Subtask
+import cn.flightfeather.thirdapp.bean.entity.Mediafile
+import cn.flightfeather.thirdapp.bean.entity.Scense
+import cn.flightfeather.thirdapp.bean.entity.Subtask
 import cn.flightfeather.thirdapp.bean.vo.ProblemlistVo
 import cn.flightfeather.thirdapp.model.event.InspectionEvent
 import cn.flightfeather.thirdapp.model.event.ProblemEvent
@@ -129,7 +129,7 @@
 
         super.onCreate(savedInstanceState)
 
-        initIconViewPager()
+//        initIconViewPager()
         initLocation()
 
         ll_show_hide_detail.setOnClickListener(this)
@@ -140,25 +140,6 @@
 
         viewModel.inspection.observe(this, Observer {
             it?.apply {
-                if (extension1 != null) {
-                    val list = extension1.split(";").map{str ->
-                        str.split(",").map {str2 ->
-                            str2.toDoubleOrNull() ?: 0.0
-                        }.takeIf { l-> l.size == 2 }.let {latLng->
-                            LatLng(latLng?.get(1) ?: 0.0, latLng?.get(0) ?: 0.0)
-                        }
-                    }
-                    drawPolyline(list)
-                    list.firstOrNull()?.let {p->
-                        myLatLngList.add(
-                                MyLatLng(
-                                        p,
-                                        drawableId = R.drawable.icon_mark_start_blue,
-                                        selected = true
-                                )
-                        )
-                    }
-                }
                 onDataLoaded(0)
             }
         })
@@ -329,8 +310,37 @@
             result = result.and(it)
         }
         if (result) {
+            initIconViewPager()
             showMenu()
             refreshMenuStatus(taskStatus)
+
+            viewModel.inspection.value?.extension1?.let{
+                val list = it.split(";").map{str ->
+                    str.split(",").map {str2 ->
+                        str2.toDoubleOrNull() ?: 0.0
+                    }.takeIf { l-> l.size == 2 }.let {latLng->
+                        LatLng(latLng?.get(1) ?: 0.0, latLng?.get(0) ?: 0.0)
+                    }
+                }
+                //閬撹矾鐩戞祴鐐瑰拰閬撹矾绫诲瀷鐨勫満鏅紝鐩存帴灞曠ず杞ㄨ抗锛涘叾浣欏満鏅彧鏈夌鐞嗗憳鍜屾斂搴滈儴闂ㄥ彲浠ユ煡鐪�
+                if (
+                        (viewModel.scene.value?.typeid?.toString() == Constant.SCENE_TYPE9 || viewModel.scene.value?.typeid?.toString() == Constant.SCENE_TYPE10)
+                        || (CommonApplication.getInstance().currentUser.usertypeid == 0.toByte() || CommonApplication.getInstance().currentUser.usertypeid == 2.toByte())
+                ) {
+                    drawPolyline(list)
+                }
+
+                list.firstOrNull()?.let {p->
+                    myLatLngList.add(
+                            MyLatLng(
+                                    p,
+                                    drawableId = R.drawable.icon_mark_start_blue,
+                                    selected = true
+                            )
+                    )
+                }
+            }
+
         } else {
             toast("璇风瓑寰呮暟鎹姞杞藉畬鎴�")
         }
@@ -573,14 +583,12 @@
 
     private fun startTracking() {
         if (
-//                viewModel.scene.value?.typeid?.toString() != Constant.SCENE_TYPE9 ||
+                viewModel.subTask.value == null ||
                 viewModel.subTask.value?.status != Domain.TASK_STATUS_RUNNING
         ) return
 
         //褰撶户缁墽琛屾鍦ㄨ繘琛屼腑鐨勪换鍔℃椂锛屾牴鎹槸鍚︽湁鍘嗗彶杞ㄨ抗璁板綍鏉ュ垽鏂槸鍚﹀紑鍚�
-        if (viewModel.inspection.value?.extension1 != null) {
-            needTracking = true
-        }
+        needTracking = true
 
         if (!needTracking || timerTaskRunning) return
 
@@ -596,8 +604,8 @@
                     timerTaskRunning = true
                 }
 
-                val lng = round(longitudeCurrent * 1000) / 1000
-                val lat = round(latitudeCurrent * 1000) / 1000
+                val lng = round(longitudeCurrent * 1000000) / 1000000
+                val lat = round(latitudeCurrent * 1000000) / 1000000
 
                 viewModel.inspection.value?.apply {
                     if (extension1 == null) {
@@ -616,9 +624,15 @@
                         val l1 = LatLng(lat, lng)
                         val l2 = LatLng(last[1], last[0])
                         val distance = AMapUtils.calculateLineDistance(l1, l2)
-                        if (distance >= 5) {
+                        if (distance >= 1 && distance < 1000 && lat != 0.0 && lng != 0.0) {
                             extension1 = "${extension1};${lng},${lat}"
-                            drawPolyline(LatLng(lat, lng))
+                            //閬撹矾鐩戞祴鐐瑰拰閬撹矾绫诲瀷鐨勫満鏅紝鐩存帴灞曠ず杞ㄨ抗锛涘叾浣欏満鏅彧鏈夌鐞嗗憳鍜屾斂搴滈儴闂ㄥ彲浠ユ煡鐪�
+                            if (
+                                    (viewModel.scene.value?.typeid?.toString() == Constant.SCENE_TYPE9 || viewModel.scene.value?.typeid?.toString() == Constant.SCENE_TYPE10)
+                                    || (CommonApplication.getInstance().currentUser.usertypeid == 0.toByte() || CommonApplication.getInstance().currentUser.usertypeid == 2.toByte())
+                            ) {
+                                drawPolyline(LatLng(lat, lng))
+                            }
                         }
                     }
                 }
@@ -628,7 +642,7 @@
     }
 
     private fun trackingDone() {
-        if (!needTracking || !timerTaskRunning) return
+        if (!timerTaskRunning) return
 
         aMap.moveCamera(CameraUpdateFactory.zoomTo(zoomLevel))
 
@@ -670,10 +684,16 @@
 
     //寮�濮嬪鑸�
     private fun startNavi() {
-        val sourceLatLng = LatLng(viewModel.scene.value?.getLatitude()!!, viewModel.scene.value?.getLongitude()!!)
-
-        val amapNavi = AmapNavi(this)
-        amapNavi.startNavi(sourceLatLng.latitude, sourceLatLng.longitude)
+        if (viewModel.scene.value != null) {
+            val sourceLatLng = LatLng(
+                    viewModel.scene.value!!.latitude,
+                    viewModel.scene.value!!.longitude
+            )
+            val amapNavi = AmapNavi(this)
+            amapNavi.startNavi(sourceLatLng.latitude, sourceLatLng.longitude)
+        } else {
+            toast("瀵艰埅鐩墠涓嶅彲鐢紝璇风◢鍚庡啀璇�")
+        }
     }
 
     override fun onClick(v: View?) {

--
Gitblit v1.9.3