From 52cab40bb0568b1b1da2035d15158154928c6464 Mon Sep 17 00:00:00 2001
From: riku <risaku@163.com>
Date: 星期二, 01 九月 2020 13:41:02 +0800
Subject: [PATCH] jarRepositories.xml
---
app/src/main/java/cn/flightfeather/thirdapp/module/inspection/InspectionDetailActivity.kt | 32 +++++++++++++++++++-------------
1 files changed, 19 insertions(+), 13 deletions(-)
diff --git a/app/src/main/java/cn/flightfeather/thirdapp/module/inspection/InspectionDetailActivity.kt b/app/src/main/java/cn/flightfeather/thirdapp/module/inspection/InspectionDetailActivity.kt
index 252856b..a089439 100644
--- a/app/src/main/java/cn/flightfeather/thirdapp/module/inspection/InspectionDetailActivity.kt
+++ b/app/src/main/java/cn/flightfeather/thirdapp/module/inspection/InspectionDetailActivity.kt
@@ -58,7 +58,10 @@
const val PROBLEM_RECHECK = 102//闂澶嶆牳
const val PROBLEM_CHECK = 103//闂瀹℃牳
const val CHANGE_CHECK = 104//鏁存敼瀹℃牳
+ const val PROBLEM_DELETE = 105
}
+
+ private var taskStatus: String = Domain.TASK_STATUS_FINISHED
/**
* 鍔犺浇瀹屾垚鐘舵�侊紝
@@ -133,9 +136,10 @@
iv_patrol_back.setOnClickListener(this)
ll_patrol_task_detail.visibility = View.GONE
+ hideMenu()
+
viewModel.inspection.observe(this, Observer {
it?.apply {
- showMenu()
if (extension1 != null) {
val list = extension1.split(";").map{str ->
str.split(",").map {str2 ->
@@ -162,7 +166,7 @@
viewModel.subTask.observe(this, Observer {
it?.let {
updateUIBySubTask(it)
- refreshMenuStatus(it.status)
+ taskStatus = it.status
onDataLoaded(1)
}
})
@@ -325,9 +329,8 @@
result = result.and(it)
}
if (result) {
- menuList.forEach {
- it.setOnClickListener(this)
- }
+ showMenu()
+ refreshMenuStatus(taskStatus)
} else {
toast("璇风瓑寰呮暟鎹姞杞藉畬鎴�")
}
@@ -385,7 +388,7 @@
val address = s.cityname + s.districtname + " " + s.location
tv_scense_address.text = address
- val contact1 = s.contacts + " " + s.contactst
+ val contact1 = s.contacts ?: "" + " " + s.contactst ?: ""
tv_scense_contact1.text = contact1
tv_call_contact1.setOnClickListener {
//鎵撶數璇�
@@ -569,8 +572,10 @@
}
private fun startTracking() {
- if (viewModel.scene.value?.typeid?.toString() != Constant.SCENE_TYPE9
- || viewModel.subTask.value?.status != Domain.TASK_STATUS_RUNNING) return
+ if (
+// viewModel.scene.value?.typeid?.toString() != Constant.SCENE_TYPE9 ||
+ viewModel.subTask.value?.status != Domain.TASK_STATUS_RUNNING
+ ) return
//褰撶户缁墽琛屾鍦ㄨ繘琛屼腑鐨勪换鍔℃椂锛屾牴鎹槸鍚︽湁鍘嗗彶杞ㄨ抗璁板綍鏉ュ垽鏂槸鍚﹀紑鍚�
if (viewModel.inspection.value?.extension1 != null) {
@@ -716,8 +721,9 @@
val intent = Intent(this, MenuProblemListActivity::class.java).apply {
putExtra("subTask", viewModel.subTask.value)
putExtra("inspection", viewModel.inspection.value)
- putExtra("scenseLat", viewModel.scene.value?.latitude)
- putExtra("scenseLng", viewModel.scene.value?.longitude)
+ putExtra("scene", viewModel.scene.value)
+ putExtra("lat", viewModel.scene.value?.latitude)
+ putExtra("lng", viewModel.scene.value?.longitude)
}
startActivity(intent)
}
@@ -726,8 +732,8 @@
val intent = Intent(this, MenuChangeActivity::class.java).apply {
putExtra("subTask", viewModel.subTask.value)
putExtra("inspection", viewModel.inspection.value)
- putExtra("scenseLat", viewModel.scene.value?.latitude)
- putExtra("scenseLng", viewModel.scene.value?.longitude)
+ putExtra("lat", viewModel.scene.value?.latitude)
+ putExtra("lng", viewModel.scene.value?.longitude)
}
startActivity(intent)
}
@@ -835,7 +841,7 @@
}
startActivity(intent)
}
- //闂瀹℃牳
+ //鏁存敼瀹℃牳
R.id.ln_patrol_change_check -> {
val intent = Intent(this, MenuChangeCheckActivity::class.java).apply {
putExtra("subTask", viewModel.subTask.value)
--
Gitblit v1.9.3