From 43242c8e7915b968bb7a6f3f22bded7704f0e40f Mon Sep 17 00:00:00 2001
From: feiyu02 <feiyu02@163.com>
Date: 星期二, 01 九月 2020 09:55:06 +0800
Subject: [PATCH] 1. 修复问题修改界面问题子项无法显示为原纪录的问题

---
 app/src/main/java/cn/flightfeather/thirdapp/module/inspection/InspectionDetailActivity.kt |   32 +++++++++++++++++++-------------
 1 files changed, 19 insertions(+), 13 deletions(-)

diff --git a/app/src/main/java/cn/flightfeather/thirdapp/module/inspection/InspectionDetailActivity.kt b/app/src/main/java/cn/flightfeather/thirdapp/module/inspection/InspectionDetailActivity.kt
index 252856b..a089439 100644
--- a/app/src/main/java/cn/flightfeather/thirdapp/module/inspection/InspectionDetailActivity.kt
+++ b/app/src/main/java/cn/flightfeather/thirdapp/module/inspection/InspectionDetailActivity.kt
@@ -58,7 +58,10 @@
         const val PROBLEM_RECHECK = 102//闂澶嶆牳
         const val PROBLEM_CHECK = 103//闂瀹℃牳
         const val CHANGE_CHECK = 104//鏁存敼瀹℃牳
+        const val PROBLEM_DELETE = 105
     }
+
+    private var taskStatus: String = Domain.TASK_STATUS_FINISHED
 
     /**
      * 鍔犺浇瀹屾垚鐘舵�侊紝
@@ -133,9 +136,10 @@
         iv_patrol_back.setOnClickListener(this)
         ll_patrol_task_detail.visibility = View.GONE
 
+        hideMenu()
+
         viewModel.inspection.observe(this, Observer {
             it?.apply {
-                showMenu()
                 if (extension1 != null) {
                     val list = extension1.split(";").map{str ->
                         str.split(",").map {str2 ->
@@ -162,7 +166,7 @@
         viewModel.subTask.observe(this, Observer {
             it?.let {
                 updateUIBySubTask(it)
-                refreshMenuStatus(it.status)
+                taskStatus = it.status
                 onDataLoaded(1)
             }
         })
@@ -325,9 +329,8 @@
             result = result.and(it)
         }
         if (result) {
-            menuList.forEach {
-                it.setOnClickListener(this)
-            }
+            showMenu()
+            refreshMenuStatus(taskStatus)
         } else {
             toast("璇风瓑寰呮暟鎹姞杞藉畬鎴�")
         }
@@ -385,7 +388,7 @@
         val address = s.cityname + s.districtname + " " + s.location
         tv_scense_address.text = address
 
-        val contact1 = s.contacts + " " + s.contactst
+        val contact1 = s.contacts ?: "" + " " + s.contactst ?: ""
         tv_scense_contact1.text = contact1
         tv_call_contact1.setOnClickListener {
             //鎵撶數璇�
@@ -569,8 +572,10 @@
     }
 
     private fun startTracking() {
-        if (viewModel.scene.value?.typeid?.toString() != Constant.SCENE_TYPE9
-                || viewModel.subTask.value?.status != Domain.TASK_STATUS_RUNNING) return
+        if (
+//                viewModel.scene.value?.typeid?.toString() != Constant.SCENE_TYPE9 ||
+                viewModel.subTask.value?.status != Domain.TASK_STATUS_RUNNING
+        ) return
 
         //褰撶户缁墽琛屾鍦ㄨ繘琛屼腑鐨勪换鍔℃椂锛屾牴鎹槸鍚︽湁鍘嗗彶杞ㄨ抗璁板綍鏉ュ垽鏂槸鍚﹀紑鍚�
         if (viewModel.inspection.value?.extension1 != null) {
@@ -716,8 +721,9 @@
                 val intent = Intent(this, MenuProblemListActivity::class.java).apply {
                     putExtra("subTask", viewModel.subTask.value)
                     putExtra("inspection", viewModel.inspection.value)
-                    putExtra("scenseLat", viewModel.scene.value?.latitude)
-                    putExtra("scenseLng", viewModel.scene.value?.longitude)
+                    putExtra("scene", viewModel.scene.value)
+                    putExtra("lat", viewModel.scene.value?.latitude)
+                    putExtra("lng", viewModel.scene.value?.longitude)
                 }
                 startActivity(intent)
             }
@@ -726,8 +732,8 @@
                 val intent = Intent(this, MenuChangeActivity::class.java).apply {
                     putExtra("subTask", viewModel.subTask.value)
                     putExtra("inspection", viewModel.inspection.value)
-                    putExtra("scenseLat", viewModel.scene.value?.latitude)
-                    putExtra("scenseLng", viewModel.scene.value?.longitude)
+                    putExtra("lat", viewModel.scene.value?.latitude)
+                    putExtra("lng", viewModel.scene.value?.longitude)
                 }
                 startActivity(intent)
             }
@@ -835,7 +841,7 @@
                 }
                 startActivity(intent)
             }
-            //闂瀹℃牳
+            //鏁存敼瀹℃牳
             R.id.ln_patrol_change_check -> {
                 val intent = Intent(this, MenuChangeCheckActivity::class.java).apply {
                     putExtra("subTask", viewModel.subTask.value)

--
Gitblit v1.9.3