From 29c6cb0031e3d1aac2e326b3a83fa78bcd380890 Mon Sep 17 00:00:00 2001
From: riku <risaku@163.com>
Date: 星期一, 21 十二月 2020 10:57:07 +0800
Subject: [PATCH] 1. 修改巡查界面刚进入快速点击巡查功能按钮导致崩溃问题; 2. 修复技防措施的地址记录信息有加号的问题
---
app/src/main/java/cn/flightfeather/thirdapp/module/inspection/InspectionDetailActivity.kt | 88 +++++++++++++++++++++++++++----------------
1 files changed, 55 insertions(+), 33 deletions(-)
diff --git a/app/src/main/java/cn/flightfeather/thirdapp/module/inspection/InspectionDetailActivity.kt b/app/src/main/java/cn/flightfeather/thirdapp/module/inspection/InspectionDetailActivity.kt
index a089439..3cde748 100644
--- a/app/src/main/java/cn/flightfeather/thirdapp/module/inspection/InspectionDetailActivity.kt
+++ b/app/src/main/java/cn/flightfeather/thirdapp/module/inspection/InspectionDetailActivity.kt
@@ -13,6 +13,7 @@
import android.view.View
import android.view.animation.AnimationUtils
import android.widget.LinearLayout
+import cn.flightfeather.thirdapp.CommonApplication
import cn.flightfeather.thirdapp.R
import cn.flightfeather.thirdapp.activity.GradeActivity
import cn.flightfeather.thirdapp.activity.MapActivity
@@ -129,7 +130,7 @@
super.onCreate(savedInstanceState)
- initIconViewPager()
+// initIconViewPager()
initLocation()
ll_show_hide_detail.setOnClickListener(this)
@@ -140,25 +141,6 @@
viewModel.inspection.observe(this, Observer {
it?.apply {
- if (extension1 != null) {
- val list = extension1.split(";").map{str ->
- str.split(",").map {str2 ->
- str2.toDoubleOrNull() ?: 0.0
- }.takeIf { l-> l.size == 2 }.let {latLng->
- LatLng(latLng?.get(1) ?: 0.0, latLng?.get(0) ?: 0.0)
- }
- }
- drawPolyline(list)
- list.firstOrNull()?.let {p->
- myLatLngList.add(
- MyLatLng(
- p,
- drawableId = R.drawable.icon_mark_start_blue,
- selected = true
- )
- )
- }
- }
onDataLoaded(0)
}
})
@@ -329,8 +311,37 @@
result = result.and(it)
}
if (result) {
+ initIconViewPager()
showMenu()
refreshMenuStatus(taskStatus)
+
+ viewModel.inspection.value?.extension1?.let{
+ val list = it.split(";").map{str ->
+ str.split(",").map {str2 ->
+ str2.toDoubleOrNull() ?: 0.0
+ }.takeIf { l-> l.size == 2 }.let {latLng->
+ LatLng(latLng?.get(1) ?: 0.0, latLng?.get(0) ?: 0.0)
+ }
+ }
+ //閬撹矾鐩戞祴鐐瑰拰閬撹矾绫诲瀷鐨勫満鏅紝鐩存帴灞曠ず杞ㄨ抗锛涘叾浣欏満鏅彧鏈夌鐞嗗憳鍜屾斂搴滈儴闂ㄥ彲浠ユ煡鐪�
+ if (
+ (viewModel.scene.value?.typeid?.toString() == Constant.SCENE_TYPE9 || viewModel.scene.value?.typeid?.toString() == Constant.SCENE_TYPE10)
+ || (CommonApplication.getInstance().currentUser.usertypeid == 0.toByte() || CommonApplication.getInstance().currentUser.usertypeid == 2.toByte())
+ ) {
+ drawPolyline(list)
+ }
+
+ list.firstOrNull()?.let {p->
+ myLatLngList.add(
+ MyLatLng(
+ p,
+ drawableId = R.drawable.icon_mark_start_blue,
+ selected = true
+ )
+ )
+ }
+ }
+
} else {
toast("璇风瓑寰呮暟鎹姞杞藉畬鎴�")
}
@@ -573,14 +584,12 @@
private fun startTracking() {
if (
-// viewModel.scene.value?.typeid?.toString() != Constant.SCENE_TYPE9 ||
+ viewModel.subTask.value == null ||
viewModel.subTask.value?.status != Domain.TASK_STATUS_RUNNING
) return
//褰撶户缁墽琛屾鍦ㄨ繘琛屼腑鐨勪换鍔℃椂锛屾牴鎹槸鍚︽湁鍘嗗彶杞ㄨ抗璁板綍鏉ュ垽鏂槸鍚﹀紑鍚�
- if (viewModel.inspection.value?.extension1 != null) {
- needTracking = true
- }
+ needTracking = true
if (!needTracking || timerTaskRunning) return
@@ -596,8 +605,8 @@
timerTaskRunning = true
}
- val lng = round(longitudeCurrent * 1000) / 1000
- val lat = round(latitudeCurrent * 1000) / 1000
+ val lng = round(longitudeCurrent * 1000000) / 1000000
+ val lat = round(latitudeCurrent * 1000000) / 1000000
viewModel.inspection.value?.apply {
if (extension1 == null) {
@@ -616,9 +625,15 @@
val l1 = LatLng(lat, lng)
val l2 = LatLng(last[1], last[0])
val distance = AMapUtils.calculateLineDistance(l1, l2)
- if (distance >= 5) {
+ if (distance >= 1) {
extension1 = "${extension1};${lng},${lat}"
- drawPolyline(LatLng(lat, lng))
+ //閬撹矾鐩戞祴鐐瑰拰閬撹矾绫诲瀷鐨勫満鏅紝鐩存帴灞曠ず杞ㄨ抗锛涘叾浣欏満鏅彧鏈夌鐞嗗憳鍜屾斂搴滈儴闂ㄥ彲浠ユ煡鐪�
+ if (
+ (viewModel.scene.value?.typeid?.toString() == Constant.SCENE_TYPE9 || viewModel.scene.value?.typeid?.toString() == Constant.SCENE_TYPE10)
+ || (CommonApplication.getInstance().currentUser.usertypeid == 0.toByte() || CommonApplication.getInstance().currentUser.usertypeid == 2.toByte())
+ ) {
+ drawPolyline(LatLng(lat, lng))
+ }
}
}
}
@@ -628,7 +643,7 @@
}
private fun trackingDone() {
- if (!needTracking || !timerTaskRunning) return
+ if (!timerTaskRunning) return
aMap.moveCamera(CameraUpdateFactory.zoomTo(zoomLevel))
@@ -653,6 +668,7 @@
} else {
it.problemcount + 1
}
+ // fixme: 2020/9/1 姝ゅ鍘熸湰鐨勯�昏緫鏄柊澧炰竴涓棶棰樺悗锛屽悓姝ユ洿鏂板贰鏌ヤ俊鎭腑鐨勯棶棰樻暟锛岄敊璇紝搴旇灏嗘鏇存柊鎿嶄綔鐩存帴鐢辨柊澧為棶棰樻帴鍙g粺涓�瀹屾垚
viewModel.updateInspection(it)
}
@@ -669,10 +685,16 @@
//寮�濮嬪鑸�
private fun startNavi() {
- val sourceLatLng = LatLng(viewModel.scene.value?.getLatitude()!!, viewModel.scene.value?.getLongitude()!!)
-
- val amapNavi = AmapNavi(this)
- amapNavi.startNavi(sourceLatLng.latitude, sourceLatLng.longitude)
+ if (viewModel.scene.value != null) {
+ val sourceLatLng = LatLng(
+ viewModel.scene.value!!.latitude,
+ viewModel.scene.value!!.longitude
+ )
+ val amapNavi = AmapNavi(this)
+ amapNavi.startNavi(sourceLatLng.latitude, sourceLatLng.longitude)
+ } else {
+ toast("瀵艰埅鐩墠涓嶅彲鐢紝璇风◢鍚庡啀璇�")
+ }
}
override fun onClick(v: View?) {
--
Gitblit v1.9.3